NeuCardio E3

  • Digital isolation technology minimized signal interference
  • Histogram and trend chart for R-R interval analysis
  • Waveform and patient information replay
  • Languages options: English, Russian and Chinese
  • Preview waveform of the currently examining patient before printing
  • Selectable of printing the analysis report and representative beats
  • Input information of patient, doctor and hospital by operator
  • The LCD brightness and contrast are adjustable
  • USB port for real-time data transmission to PC
  • Optional SD card supporting the maximum data capacity of 2GB, up to 10000 copies of patient data storage

 

Specifications

Main unit
LeadStandard 12-lead
Acquisition mode Simultaneous 12-lead acquisition
Recording formatAutomatic 1 channel/ Automatic 2 channel/ Automatic 3 channel/ Rhythm 3 channel/ Manual 1 channel/ Manual 2 channel/ Manual 3 channel
Recording Mode
AutomaticRecord in appropriate format and automatic lead switch with measurement and analysis function.
ManualRecord in appropriate format and manual lead switch without measurement or analysis function
Long term recordingRecord for a long term (30-180 sec.) and rhythm analysis
Measurement parametersVentricular rate, PR interval, QRS time limit, QT/QTC interval, P/QRS/T axis, RV5/SV1 amplitude and RV5+SV1 amplitude
Filters AC, drift and myoelectric filters
Input CIR current≤0.1μA
Input impedance>50MW
Patient leak current<10μA
Time constant≥3.2s
Frequency response0.05~150Hz
Noise level<15μVp-p
Sensitivity threshold  ≤20μV
Paper speed4 levels as 6.25, 12.5, 25, 50mm/s, tolerance≤5%
Sensitivity4 levels as 2.5, 5, 10, 20mm/mV
Calibration voltage1mV±3%
Input circuitFloating circuit input
Recorder
Recording modeThermal array printing system
8 points/mm (perpendicular)
40 points/mm (horizontal, 25 mm/sec.)
Paper speed6.25, 12.5,25,50 mm/s±5%
Recording paper specification63mm×30m or 63mm×20m, roll paper
63mm×75mm×20m, fan- fold paper
Others
Lead linesECG-9801.F01.00
Display on LCDThe whole instrument work status, time, heart rate, and with the backlight
Safety ClassificationIEC60601-1  ClassⅠ Type CF
AC power supply100~240V,50/60Hz,50VAs
DC power supplySealed maintenance-free rechargeable battery, 14.8V-1550mAh
Fuse specificationT1.6A/250V (Built in the instrument)
DC time –lag fuseSelf-recovery fuse of 3.15A/250V (Built in the instrument)
Dimensions and Weight
Length × width × height 268mm×206mm×67.5mm
WeightAbout 3.3 kg
Transportation
Environment temperature-20℃~+55℃
Relative humidity25%~95% (without condensation)
Air pressure500hPa~1060hPa
Storage
Environment temperature-10℃~+40℃
Relative humidity25%~80%
Air pressure500hPa~1060hPa
Using
Environment temperature+5℃~+40℃
Relative humidity25%~95%
Air pressure700hPa~1060hPa